Related Experiment Video
Updated: May 6, 2026

Practical Aspects of Sample Preparation and Setup of 1H R1ρ Relaxation Dispersion Experiments of RNA
Published on: July 9, 2021
Sample conditions to avoid pH distortion in RP-LC
Jörgen Samuelsson1, Patrik Forssén, Torgny Fornstedt
1Department of Engineering and Chemical Sciences, Karlstad University, Karlstad, Sweden.
Abstract:
Band deformations might take place for acids and bases in preparative applications and adsorption studies where it is necessary to use overloaded injections. In this study, we focus on how deformations can be prevented without using highly concentrated buffers that may precipitate in the eluent. We have systematically investigated how the elution zones depend on which protolytic form the analyte has when it is dissolved. Basic and acidic model compounds are investigated using eluents with different pH values and the resulting elution profiles are compared when the analytes are dissolved in their protonated and deprotonated form, i.e., in uncharged form or as different kinds of salts. Depending on the analyte's protolytic form, a sample zone is created at the column inlet whose pH deviates, more or less, from the bulk eluent's. If the local adsorption strength in this sample zone is greater than the bulk eluent's, the elution profiles are compressed. Under opposite conditions, the eluted bands are more or less deformed and may even be split; completely different deformations can even take place for different kinds of salt combinations. Explanations of these, and other, effects, together with detailed guidelines for proper sample preparation to avoid peak deformations, are given.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Parallel RLC Circuits
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
Characteristics of Series Resonant Circuit
Series RLC Circuit without Source
RLC Series Circuits
RLC Series Circuits: Impedance
Thus, the magnitude of the impedance is given by the following equation,
Design Example: Underdamped Parallel RLC Circuit
Starting with a fixed...