Related Experiment Video
Updated: May 6, 2026

Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
Sequential injection method for rapid and simultaneous determination of 236U, 237Np, and Pu isotopes in seawater
Jixin Qiao1, Xiaolin Hou, Peter Steier
1Center of Nuclear Technologies, Technical University of Denmark, DTU Risø Campus , DK-4000 Roskilde, Denmark.
Abstract:
An automated analytical method implemented in a novel dual-column tandem sequential injection (SI) system was developed for simultaneous determination of (236)U, (237)Np, (239)Pu, and (240)Pu in seawater samples. A combination of TEVA and UTEVA extraction chromatography was exploited to separate and purify target analytes, whereupon plutonium and neptunium were simultaneously isolated and purified on TEVA, while uranium was collected on UTEVA. The separation behavior of U, Np, and Pu on TEVA-UTEVA columns was investigated in detail in order to achieve high chemical yields and complete purification for the radionuclides of interest. (242)Pu was used as a chemical yield tracer for both plutonium and neptunium. (238)U was quantified in the sample before the separation for deducing the (236)U concentration from the measured (236)U/(238)U atomic ratio in the separated uranium target using accelerator mass spectrometry. Plutonium isotopes and (237)Np were measured using inductively coupled plasma mass spectrometry after separation. The analytical results indicate that the developed method is robust and efficient, providing satisfactory chemical yields (70-100%) of target analytes and relatively short analytical time (8 h/sample).