Background:
Blood gas analysis is important for assessment of ventilatory function. Traditionally, arterial analysis has been used. A method for mathematically arterialising venous blood gas values has been developed. Our aim was to validate this method in patients undergoing non-invasive ventilation (NIV) in an emergency department (ED).
Materials And Methods:
This post hoc substudy of a prospective cohort study included adult patients undergoing NIV for acute respiratory compromise. When arterial blood gas analysis was required for clinical purposes, a venous sample was also drawn. Mathematically arterialised values were calculated independent of arterial values. Primary outcome of interest was agreement between mathematically arterialised venous and arterial values for pH and pCO2. Bland-Altman agreement plot analysis was used.
Results:
Eighty sample-pairs (58 patients) were studied. Mean difference for arterial pH (actual-calculated) was 0.01 pH units (95% limits of agreement: -0.04, 0.06). Mean difference for pCO2 (actual-calculated) was -0.06 kPa (95% limits of agreement: -1.34, 1.22).
Conclusions:
For patients undergoing NIV in an ED, agreement between mathematically arterialised venous values and arterial values was close for pH but only moderate for pCO2. Depending on clinician tolerance for agreement, this method may be a clinically useful alternative to arterial blood gas analysis in the ED.
More Related Videos
05:03Brain Death Induction in Mice Using Intra-Arterial Blood Pressure Monitoring and Ventilation via Tracheostomy
Published on: April 17, 2020
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
Gas Exchange and Transport