Reliability and validity of a wireless microelectromechanicals based system (keimove™) for measuring vertical jumping
Bernardo Requena1, Inmaculada García, Francisco Requena
1Faculty of Sport, University of Pablo de Olavide , Spain.
Journal of Sports Science & Medicine
|October 19, 2013
Summary
The Keimove™ system, a wireless microelectromechanicals (MEMs) device, accurately measures flight time and takeoff velocity during counter-movement jumps (CMJ). This portable and cost-effective tool offers valid and reliable CMJ performance assessment for athletes.
Area of Science:
- Sports Science and Biomechanics
- Human Movement Analysis
- Wearable Technology in Sports
Background:
- Accurate measurement of jump performance is crucial for athlete assessment and training.
- Traditional methods for measuring counter-movement jump (CMJ) parameters can be cumbersome or expensive.
- Microelectromechanical systems (MEMs) offer potential for portable and cost-effective performance monitoring.
Purpose of the Study:
- To validate and assess the reliability of the Keimove™ MEMs-based system for measuring CMJ flight time and takeoff velocity.
- To compare Keimove™ measurements against criterion reference methods, including high-speed cameras and force platforms.
Main Methods:
- Thirty professional soccer players performed three counter-movement jumps (CMJs).
- The Keimove™ system was simultaneously compared with a high-speed camera (HSC) and a force platform synchronized with a linear position transducer (FP+LPT).
- Flight time and takeoff velocity were recorded by all systems for analysis.
Main Results:
- High Pearson correlation coefficients (r = 0.99) were found for flight time between Keimove™ and criterion methods (HSC, FP+LPT).
- Significant, though lower, correlations were observed for takeoff velocity between Keimove™ and FP+LPT.
- No significant differences in mean values for flight time and takeoff velocity were found across the devices; high reliability (ICC: 0.92-0.97) was demonstrated.
Conclusions:
- The Keimove™ system is a valid and reliable instrument for measuring flight time and takeoff velocity during CMJ testing.
- This MEMs-based system provides a portable and cost-effective alternative for assessing CMJ performance.
- The Keimove™ system's wireless design and lumbar attachment offer practical advantages for athletes.