Related Experiment Video
Updated: May 6, 2026

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Published on: June 3, 2020
Outside-in continuous suturing is superior to interrupted suturing for repairing peripheral meniscus lesions: an in
Ryan Breland1, John Nyland, Yee Han D Lee
1Division of Sports Medicine, Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky, U.S.A.
Purpose:
This in vitro biomechanical study using a porcine model compared peripheral longitudinal vertical meniscus lesion (PLVML) outside-in suture repair fixation strength using either interrupted or continuous "N" configuration No. 2-0 braided polyester sutures.
Methods:
Porcine lateral menisci were randomly assigned to group 1 (continuous) or group 2 (interrupted). Standardized PLVMLs were created in each specimen. Repaired specimens were placed in a specially designed clamp and loaded into a servohydraulic device. Specimens underwent preconditioning for 10 cycles (0.1 Hz, 5 to 20 N) and 500 submaximal loading cycles (0.5 Hz, 5 to 20 N), before load-to-failure testing (12.5 mm/s). A 30-second pause after preconditioning and after 10, 100, and 500 submaximal loading cycles enabled standardized digital photographs to be taken for gapping measurement determination. The failure mode was documented.
Results:
Displacement and gapping during preconditioning and submaximal loading cycles did not differ between groups. Group 1 withstood a greater failure load (mean, 118.3 N; 95% confidence interval [CI], 97.2 to 139.4 N) than group 2 (mean, 63.7 N; 95% CI, 51.2 to 76.2 N) (P < .0001) and displacement during load-to-failure testing (mean, 5.3 mm; 95% CI, 4.2 to 6.5 mm) than group 2 (mean, 3.2 mm; 95% CI, 2.1 to 4.3 mm) (P = .005). Group 1 failed by suture breakage or suture pulling through tissue, whereas group 2 primarily failed by knot slippage (P < .0001).
Conclusions:
Group displacement and gapping differences were not observed after 500 submaximal loading cycles. PLVMLs repaired with a continuous N configuration, however, withstood greater load at failure and greater displacement before failure than repairs that used interrupted sutures.
Clinical Relevance:
Continuous suture in an N configuration may improve PLVML repair fixation strength.