Related Experiment Video
Updated: May 6, 2026

A Colorimetric Method for Measuring Iron Content in Plants
Published on: September 7, 2018
Interference of ferric ions with ferrous iron quantification using the ferrozine assay
Jeongdae Im1, Jaejin Lee, Frank E Löffler
1Department of Microbiology, University of Tennessee, Knoxville, TN 37996, USA; Center for Environmental Biotechnology, University of Tennessee, Knoxville, TN 37996, USA.
Abstract:
The ferrozine assay is a widely used colorimetric method for determining soluble iron concentrations. We provide evidence for a heretofore unrecognized interference of ferric ions (Fe(3+)) on ferrous iron (Fe(2+)) measurements performed in the dark. Fe(3+) concentrations affected the absorbance measurements, which linearly increased with incubation time.
More Related Videos
05:36Author Spotlight: Assessing the Impact of Novel Iron Chelators on Cancer Cell Metabolism
Published on: February 23, 2024
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Complexometric Titration: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...