Related Experiment Video
Updated: May 6, 2026

08:10
Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
2.9K
The atrial electromechanical coupling time: what does it predict in patients with paroxysmal atrial fibrillation?
B Bugan1, E Yildirim, E Yalçinkaya
1Cardiology Service, Malatya Military Hospital, Turkey. bbugan@hotmail.com.
European Review for Medical and Pharmacological Sciences
|October 22, 2013
Abstract
No abstract available in PubMed .
Related Concept Videos
Correlation between ECG and Cardiac Cycle
13.7K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
13.7K
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
1.2K
Arrhythmia is a condition characterized by an irregular heart rhythm, with ECG changes that differ based on its origin and nature. The types of arrhythmias discussed below include atrial, junctional, and ventricular arrhythmias.Atrial ArrhythmiasPremature Atrial Complexes (PACs): PACs are early atrial beats caused by stress, caffeine, alcohol, electrolyte imbalances, hypoxia, hyperthyroidism, or certain medications (e.g., bronchodilators and decongestants). The ECG shows early P waves with an...
1.2K
Dysrhythmias III: Characteristics of Dysrhythmias
714
Dysrhythmias, also known as arrhythmias, are irregular heart rhythms that result from abnormal electrical activity in the heart, affecting its ability to circulate blood efficiently. Tachyarrhythmias, a subset of dysrhythmias, are characterized by abnormally fast heart rates exceeding 100 beats per minute. Here are some types of tachyarrhythmias with their distinct ECG features:Sinus Tachycardia:Sinus tachycardia presents a regular heart rhythm with an increased rate of 101-180 beats per...
714
Dysrhythmias IV: Characteristics of Bradyarrhythmias
788
Bradyarrhythmias are cardiac rhythm disorders characterized by a slower-than-normal heart rate, typically defined as fewer than 60 beats per minute. Some of which are discussed here:Sinus BradycardiaSinus bradycardia presents a heart rate lower than 60 beats per minute, with a regular rhythm originating from the SA node. The ECG typically shows normal P waves preceding each QRS complex, a normal PR interval (0.12 to 0.20 seconds), and a normal QRS duration (0.06 to 0.10 seconds).First-Degree AV...
788
Cardiac Action Potential
12.1K
Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
12.1K
Electrophysiology of Normal Cardiac Rhythm
7.8K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
7.8K

