Related Experiment Video
Updated: May 6, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy
Toshio Ohashi1, Tetsuo Momma, Shoji Yamashita
1Department of Radiology, Keio University School of Medicine, Tokyo ; Department of Radiology, National Hospital Organization Saitama Hospital, Saitama.
Purpose:
Post-implant dosimetric assessment is essential for optimal care of patients receiving prostate brachytherapy. In most institutions, post-implant computed tomography (CT) is performed in the supine position. This study aimed to assess variability in dosimetric parameters with postural changes during acquisition of post-implant CT scans.
Material And Methods:
In total, 85 consecutive patients were enrolled in this study. Fifty-three patients underwent seed implantation alone, and the remaining 32 received a combination of seed implantation and external beam radiotherapy. For post-implant analyses, CT scans were obtained in two patient positions, supine and prone. To evaluate differences in dosimetric parameters associated with postural change, the dosimetric data obtained in the supine position were defined as the standard.
Results:
The median prostate volume was 22.4 ml in the supine and 22.5 ml in the prone position (p = 0.51). The median prostate D90 was 120.1% in the supine and 120.3% in the prone position, not significantly different. The mean prostate V100 was 97.1% in the supine and 97.0% in the prone position, again not significantly different. Median rectal V100 in supine and prone positions were 0.42 ml and 0.33 ml, respectively (p < 0.01). Rectal D2cc was also significantly decreased in the prone as compared with the supine position (median, 59.1% vs. 63.6%; p < 0.01). A larger post-implant prostate volume was associated with decreased rectal doses in the prone position.
Conclusions:
Though there were no significant differences among prostate D90 assessments according to postural changes, our results suggest that post-implant rectal doses decreased in the prone position.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Imaging Studies II: Ultrasonography