Related Experiment Video
Updated: May 6, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Electronic bed weighing vs daily fluid balance changes after cardiac surgery
Antoine Guillaume Schneider1, Christopher Thorpe, Kerrin Dellbridge
1Intensive Care Unit, Department of Intensive Care, Austin Health, 3084 Heidelberg Australia; Warringal Private Hospital, 3084 Heidelberg Australia.
Purpose:
The purpose of this study is to establish the validity and reliability of measuring weight in critically ill patients with electronic weighing beds.
Methods:
All patients admitted to a private intensive care unit (ICU) after cardiac surgery over a 7-month period were weighed on admission and then twice daily (1200 and 2400 hours) using electronic weighing beds (Hill-Rom, Batesville, AR). For each measurement, nonremovable items were recorded, and an average value was deducted from measured weight. We compared differences in body weights (BWs) between 2 consecutive 12-hour periods with the corresponding fluid balance (FB). In addition, we compared weights obtained with electronic weighing beds with those obtained with a regular calibrated scale on ICU discharge.
Results:
We obtained data in 103 patients for 414 (75.5%) of 548 of all possible BW measurements. On average, we identified a total of 3.5 kg (SD, 1.4) of nonremovable items on patients' beds. The correlation between 12-hourly changes in BW and FB was weak (r = 0.28; 95% confidence interval [CI], 0.17-0.39), even after correction for insensible fluid losses (r = 0.27; 95% CI, 0.15-0.38) and when only values obtained in intubated patients were taken into account (r = 0.34; 95% CI, 0.16-0.49). Similarly, limits of agreements were wide (95% CI, -3.3 to 3.5 kg). There was also poor agreement between weights obtained on electronic beds and those obtained on the regular scale on ICU discharge (95% CI, -7.6 to 7.6 kg).
Conclusion:
Body weight measured by electronic weighing beds does not seem sufficiently robust or accurate to replace daily FB in ICU. The clinical value of purchasing such beds remains uncertain.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
07:59Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Heart Failure VI: Adjunct Therapies
Hemodialysis III: Nursing Management
Disorder of Water Balance
Dehydration
Dehydration occurs when the body loses fluids (particularly water).
Causes:
The major causes of dehydration include excessive sweating, fever, vomiting, diarrhea, and diuresis.
Signs and Symptoms:
Symptoms primarily include intense...
Heart Failure VII: Nursing Interventions
Mitral Regurgitation IV: Nursing Management