The effect of light-curing access and different resin cements on apical bond strength of fiber posts
Purpose:
This study evaluated the effect of light-curing access on the bond strength of fiber glass posts to the apical area of bovine roots using self-adhesive cement or dual-cured cement with an etch-and-rinse adhesive system.
Materials And Methods:
The root canals of 60 bovine teeth were endodontically treated and filled. A 15-mm-length post space was prepared and roots were randomly divided into three groups, simulating the levels of light-curing access: coronal (C), with 15-mm post space; middle (M), in which the coronal thirds of roots were cut out, leaving a 10-mm post space; and apical (A), in which the coronal and middle thirds of roots were cut out, leaving a 5-mm post space. Fiber glass posts (Reforpost # 3, Angelus) were cemented with RelyX U100 (3M ESPE) or RelyX ARC/Scotchbond Multi Purpose Plus (SBMP) (3M ESPE) (n=10) and light-cured. After 24 hours, the apical thirds of roots were sectioned perpendicularly to the long axis and submitted to a push-out test (0.5 mm/min, 200 N). The Kruskal-Wallis test compared the three levels of light-curing access, and the Mann-Whitney test compared the cements.
Results:
The bond strength was significantly higher in the groups C (p=0.028) and M (p=0.016) when U100 was used, whereas it was similar for both cements in group A. The bond strengths of posts cemented with ARC/SBMP were significantly higher in group A compared to group C (p=0.031).
Conclusions:
The type of cement used and the light-curing access level influenced the bond strength between glass fiber posts and root canals. The bond strength of the RelyX ARC/SBMP cement proved to be more dependent on photoactivation than was the RelyX U100 cement. The light-curing access level did not influence the apical bond strength of RelyX U100.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:37Evaluating the Effects of Different Polishing Methods on Color Stability of Dental Restorations in Pediatric Dentistry
Published on: June 6, 2025
Related Concept Videos
Bonding and Strength of Aggregate
Accelerated Curing of Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Curing of Concrete