Related Experiment Video
Updated: May 6, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Simultaneous liquid-liquid extraction and dispersive solid-phase extraction as a sample preparation method to
1Department of Analytical Chemistry, Faculty of Sciences/I.U. CINQUIMA, Campus Miguel Delibes, University of Valladolid, Paseo de Belén 7, 47011 Valladolid, Spain.
Abstract:
A sample preparation procedure that combines a liquid-liquid extraction (LLE) with a dispersive solid-phase extraction (DSPE) has been devised to determine residues of four phenoxyacid herbicides, two aminopolycarboxylic acids and five acidic anti-inflammatory drugs in small volumes of river water samples. Two aliquots of acetone (3 and 0.5 mL) were used to extract the analytes from a 10 mL water sample at pH 2 containing 5 mg of octadecylsilane (ODS) sorbent and NaCl at a 5.5 M concentration. Acetone was isolated by the salting-out effect, collected, evaporated and the extract was treated with BF3/methanol to obtain the methyl esters of the analytes and determine them by GC with mass spectrometric detection. Recoveries were comprised between 82% and 114% with relative standard deviations about 5-15% (n=5) within a concentration range about 0.03-44 µg L(-1). The amount of ODS added to sample resulted to be a significant factor in the recovery for most of the analytes as deduced from an experimental design; the sample pH was not a so critical factor. A robustness study of the proposed sample preparation was carried out as defined by Youden and Steiner and an estimation of the uncertainties of the measured concentrations was made following the EURACHEM/CITAC guidelines, too.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...