Related Experiment Video
Updated: May 6, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Validity of the modified conconi test for determining ventilatory threshold during on-water rowing
Jorge Villamil Cabo1, Pablo Martinez-Camblor, Miguel Del Valle
1Sport Medicine School, University of Oviedo , Spain.
Abstract:
The objectives of this study were to design a field test based on the Conconi protocol to determine the ventilatory threshold of rowers and to test its reliability and validity. A group of sixteen oarsmen completed a modified Conconi test for on-water rowing. The reliability of the detection of the heart rate threshold was evaluated using heart rate breaking point in the Conconi test and retest. Heart rate threshold was detected in 88.8% of cases in the test-retest. The validity of the modified Conconi test was evaluated by comparing the heart rate threshold data acquired with that obtained in a ventilatory threshold test (VT2). No significant differences were found for the values of different intensity parameters i.e. heart rate (HR), oxygen consumption (VO2), stroke rate (SR) and speed (S) between the heart rate threshold and the ventilatory threshold, (170.9 ± 6.8 vs. 169.3 ± 6.4 beats·min(-1); 42.0 ± 8.6 vs. 43.5 ± 8.3 ml·kg(-1)·min(-1); 25.8 ± 3.3 vs. 27.0 ± 3.2 strokes·min(-1) and 14.4 ± 0.8 vs. 14.6 ± 0.8 km·h(-1)). The differences in averages obtained in the Conconi test-retest were small with a low standard error of the mean. The reliability data between the Conconi test-retest showed low coefficients of variations (CV) and high intraclass correlation coefficients (ICC). The total errors for the Conconi test-retest are low for the measured variables (1.31 HR, 0.87 VO2, 0.65 SR, and 0.1 S). The Bland- Altman's method for analysis validity showed a strong concordance according to the analyzed variables. We conclude that the modified Conconi test for on-water rowing is a valid and reliable method for the determination of the second ventilatory threshold (VT2). Key pointsThe Modified Conconi test for on-water rowing is a simple and non-invasive method for the determination of anaerobic threshold for on-water rowing.The modified Conconi protocol for rowing was also shown to be a valid protocol for the calculation of the second ventilatory threshold using the ventilatory method.The Bland-Altman analysis suggests an adequate concordance for the modified Conconi test with the ventilatory method for the measurement of the ventilatory threshold.
More Related Videos
07:32Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities I