Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Assessment of Ventilation II: Respiratory Depth and Rhythm01:29

Assessment of Ventilation II: Respiratory Depth and Rhythm

2.9K
Respiratory Depth
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
2.9K
Pulmonary Function Tests01:25

Pulmonary Function Tests

1.2K
Pulmonary Function Tests (PFTs)
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
1.2K
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

3.8K
Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
3.8K
Suctioning the Nasopharyngeal Airway01:29

Suctioning the Nasopharyngeal Airway

6.6K
Nasopharyngeal suctioning is a procedure to remove secretions from the upper part of the respiratory tract that the patient cannot clear independently. It helps maintain airway patency and prevents complications such as aspiration pneumonia.
Equipment Required
6.6K
Respiratory Volumes01:15

Respiratory Volumes

3.1K
Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
3.1K
Administering Oxygen by Nasal Cannula01:29

Administering Oxygen by Nasal Cannula

6.2K
Oxygen therapy is critical to patient care, especially for those struggling with respiratory issues. This intervention increases the oxygen concentration in the lungs, enhancing the amount of oxygen transported to the body's tissues. One standard method of delivering supplemental oxygen is through a nasal cannula, a non-invasive device that provides low to medium oxygen concentrations.
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
6.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Home Spirometry as a Clinical Trial Endpoint in People with Cystic Fibrosis: Results of the OUTREACH Study.

Annals of the American Thoracic Society·2026
Same author

Maternal obesity alters adipogenic potential and mitochondrial maximal respiration in infant mesenchymal stem cells.

Frontiers in endocrinology·2026
Same author

Understanding Nebulizer Utilization by Patients and Healthcare Providers: A COPD Foundation Nebulizer Consortium Survey Study.

International journal of chronic obstructive pulmonary disease·2026
Same author

Authors' response.

Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology·2026
Same author

Technology and Human Support Systems in Decentralized Studies: A Participant-Centered Case Study in Cystic Fibrosis.

AMIA ... Annual Symposium proceedings. AMIA Symposium·2026
Same author

Promoting Breastfeeding Among Latina Women in a Community Pediatric Clinic.

Journal of immigrant and minority health·2025

Related Experiment Video

Updated: May 6, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
13:10

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique

Published on: May 15, 2013

59.1K

Longitudinal evaluation of compressor/nebulizer performance.

Samah Awad1, David K Williams2, Ariel Berlinski3

  • 1Pulmonology Section, Department of Pediatrics, College of Medicine, University of Arkansas for Medical Sciences, Little Rock, Arkansas.Department of Pediatrics. College of Medicine, Jordan University of Science and Technology, Irbid, Jordan.

Respiratory Care
|October 24, 2013
PubMed
Summary

Long-term use of compressor/nebulizers significantly impacts their performance, with the Pari Vios brand showing declines in pressure and two units failing. Monitoring flow and pressure can predict compressor failure in cystic fibrosis patients.

Keywords:
Compressoraerosolbreathing simulationcystic fibrosisflownebulizerparticle sizepressure

More Related Videos

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
07:56

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models

Published on: November 11, 2020

3.4K
Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
06:11

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults

Published on: February 9, 2022

9.3K

Related Experiment Videos

Last Updated: May 6, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
13:10

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique

Published on: May 15, 2013

59.1K
Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
07:56

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models

Published on: November 11, 2020

3.4K
Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
06:11

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults

Published on: February 9, 2022

9.3K

Area of Science:

  • Medical Devices
  • Respiratory Therapy
  • Cystic Fibrosis Research

Background:

  • Inhaled medications are crucial for cystic fibrosis (CF) lung health management.
  • Patients with CF use compressor/nebulizer units extensively (100-120 min/day).
  • Limited data exist on the long-term performance of these essential devices.

Purpose of the Study:

  • To evaluate the longitudinal performance of commonly used compressor/nebulizer units over 24 weeks.
  • To determine if typical usage patterns affect device characteristics and drug delivery.
  • To hypothesize that prolonged use impacts compressor/nebulizer performance.

Main Methods:

  • Tested four new compressor/reusable nebulizer units from three brands (Pari Vios, Pulmo-Aide, Inspiration Elite).
  • Operated units for 1 hour twice daily, 5 days/week for 24 weeks.
  • Measured flow/pressure characteristics and aerosol parameters (particle size, inhaled mass) at regular intervals.

Main Results:

  • Pari Vios showed significant declines in mean pressure (MP) and pressure at nebulizer (P/NEB) over time.
  • Two Pari Vios units malfunctioned within the 24-week study period.
  • Other brands maintained performance, though maximal flow (MF) and MF/NEB varied significantly between brands.

Conclusions:

  • Extended use of compressor/nebulizers under CF-like conditions alters their performance.
  • Pari Vios demonstrated the most significant performance degradation and failure rate.
  • Measuring maximal flow (MF) and MF/NEB may help identify devices at risk of failure.