Related Experiment Video
Updated: May 6, 2026

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Comparison of rowing on a concept 2 stationary and dynamic ergometer
Aaron Benson1, Julianne Abendroth, Deborah King
1Department of Exercise and Sport Sciences, Center for Health Sciences, Ithaca College , Ithaca, NY, USA.
Abstract:
Biomechanical and physiological responses to rowing 1000 m at a power output equivalent to a 2000 m race were compared in 34 collegiate rowers (17 women, 17 men) rowing on a stationary and dynamic Concept 2 ergometer. Stroke ratio, peak handle force, rate of force development, impulse, and respiratory exchange ratio decreased by 15.7, 14.8, 10.9, 10.2 and 1.9%, respectively, on the dynamic ergometer. In contrast, percent time to peak force and stroke rate increased by 10.5 and 12.6%, respectively, during dynamic ergometry; the changes in stroke rate and impulse were greater for men than women. Last, VO2 was 5.1% higher and efficiency 5. 3% lower on the dynamic ergometer for men. Collegiate rowers used higher stoke rates and lower peak stroke forces to achieve a similar power output while rowing at race pace on the dynamic ergometer, which may have increased the cardiopulmonary demand and possibly reduced force production in the primary movers. Differences were more pronounced in males than females; this dichotomy may be more due to dynamic ergometer familiarity than sex. Key pointsWhen rowing at a constant power output, all rowers used higher stroke rates and lower stroke forces on the Concept 2 Dynamic ergometer as compared to the Concept 2 Stationary ergometer.When rowing at a constant power output, cardiopulmonary demand was higher for all rowers, as measured by heart rate, on the Concept 2 Dynamic ergometer as compared to the Concept 2 Stationary ergometer.When rowing at a constant power output, efficiency was lower for male rowers on the Concept 2 Dynamic ergometer as compared to the Concept 2 Stationary ergometer.
More Related Videos
Related Concept Videos
Eccentric Loading
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Static Equilibrium - I
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Static Equilibrium - II

