Related Experiment Video
Updated: May 6, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Effect of supine versus sitting position on noninvasive assessment of aortic pressure waveform: a randomized
D Vrachatis1, T G Papaioannou2, A Konstantopoulou3
11] Hypertension Center and Cardiovascular Research Laboratory, 1st Department of Propaedeutic Medicine, 'Laiko' Hospital Medical School, National and Kapodistrian University of Athens, Athens, Greece [2] Biomedical Engineering Unit, 1st Department of Cardiology, 'Hippokration' Hospital, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Abstract:
Biomarkers derived noninvasively from the aortic blood pressure (BP) waveform provide information regarding cardiovascular (CV) risk independently of brachial BP (bBP). Although body position has significant impact on the assessment of bBP, its effect on aortic hemodynamics remains unknown. This study investigated the changes in both brachial and aortic hemodynamics, between the supine and sitting position. In this randomized cross-over study, the bBP and the aortic pressure waveform were assessed after a 5 min rest (sitting and supine in randomized order); aortic BP, pulse pressure (PP) amplification, augmentation index (AIx) and subendocardial viability index (SEVR) were assessed. Sixty-one subjects were examined (36 males, mean age 50±12 years). Mean BP did not differ between the sitting and supine position (110.8±13.7 vs 110.9±14.9, respectively, P=0.945). However, significant difference between the sitting and supine position in brachial PP (45.9±16.0 vs 52.6±15.6, respectively, P<0.001), aortic PP (36.7±15.2 vs 43.1±13.9, P<0.001), PP amplification (1.28±0.1 vs 1.23±0.1, P<0.001), AIx (26.9±11.9 vs 31.1±10.2, P<0.001) and SEVR (179.6±25.7 vs 161.2±25.8, P<0.001) were found. Review of the literature identified underestimation of the role of body position on aortic hemodynamics. In conclusion, increased PP in both the aorta and brachial artery were found in the supine compared to the sitting position. Reduced PP amplification and SEVR were further observed in the supine position, due to increased pressure wave reflections (AIx).
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: