Background:
Blood pressure measurement is an essential clinical skill that can readily be assessed in objective structured clinical examination (OSCE). While the use of simulators can enhance test validity and reliability, the given clinical context may also affect student performance.
Aims:
To investigate the impact of variations in clinical context on blood pressure measurement in a simulator-based OSCE.
Method:
We randomized 162 first-year medical students into four groups that received different lead-in statements before measuring blood pressure on a manikin simulator. These statements described hypothetical patients with different likelihoods of having systemic hypertension.
Results:
The lead-in that described the highest likelihood of hypertension was associated with significantly higher reported readings and lower accuracy. The lead-in that suggested normality yielded the best performance.
Conclusion:
Student performance in simulator-based OSCE may be affected by the clinical context provided. However, we argue that construct validity should be viewed in light of the application of a test, in that patients may also present with different cues and likelihoods of having hypertension. Variations in construct design should be further explored to enhance the training and assessment of clinical competence that reflects the unpredictability encountered in daily clinical practice.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Errors occurring during blood pressure monitoring
Several factors...