Related Experiment Video
Updated: May 6, 2026

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Quantification of linezolid in serum by LC-MS/MS using semi-automated sample preparation and isotope dilution
Background:
Linezolid serum concentrations have been shown to be highly variable in critically ill patients with often sub-therapeutic drug levels regarding minimal inhibitory concentrations for relevant pathogens. Consequently, therapeutic drug monitoring of linezolid must be considered, requiring a reliable and convenient analytical method. We therefore developed and validated an LC-MS/MS method applying isotope dilution internal standardization and on-line solid phase extraction for serum linezolid quantification.
Methods:
Sample preparation was based on protein precipitation and on-line solid phase extraction with two-dimensional liquid chromatography and column switching. Three-fold deuterated linezolid was used as the internal standard. The method was validated involving two separate LC-MS/MS systems covering the concentration range of 0.13-32 mg/L. The run time was 4 min.
Results:
Validation revealed good analytical performance, with inaccuracy <6% and imprecision of <7.3% (CV) for six quality control samples (0.38-16.0 mg/L). The method was found to be robust during the validation process and during a pharmacokinetic study so far involving 600 samples. Comparative measurements on two LC-MS/MS systems revealed close agreement.
Conclusions:
This LC-MS/MS assay described herein is a convenient, robust and reliable method for linezolid quantification in serum which can be routinely applied using different LC-MS/MS systems. The method can be used for clinical studies and subsequent TDM of linezolid.