Related Experiment Video
Updated: May 6, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
SPECT-CT Assessment of Pseudarthrosis after Spinal Fusion: Diagnostic Pitfall due to a Broken Screw
Olivier Rager1, Gaël Amzalag, Arthur Varoquaux
1Nuclear Medicine Department, Geneva University Medical Center, Faculty of Medicine, University of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva, Switzerland.
Abstract:
A 43-year-old drug addicted female was referred for a L5-S1 posterolateral in situ fixation with autologous graft because of an L5/S1 severe discopathy with listhesis. After six months, low back pain recurred. A Tc-99m HDP SPECT-CT diagnosed a pseudarthrosis with intense uptake of the L5-S1 endplates and a fracture of the right S1 screw just outside the metal-bone interface without any uptake or bone resorption around the screw. The absence of uptake around a broken screw is a pitfall that the physician should be aware of.
More Related Videos
05:57A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017