Related Experiment Video
Updated: May 6, 2026

Analysis of Lymph Node Volume by Ultra-High-Frequency Ultrasound Imaging in the Braf/Pten Genetically Engineered Mouse Model of Melanoma
Published on: September 8, 2021
Diagnostic value of B-RAF(V600E) in difficult-to-diagnose thyroid nodules using fine-needle aspiration: systematic
Yongsheng Jia1, Yang Yu, Xiaolong Li
1Thyroid and Neck Department, Tianjin Medical University Cancer Institute and Hospital, Tiyuanbei, Hexi District, Tianjin, China, 300060.
Abstract:
Fine-needle aspiration (FNA) is routinely used in the preoperative evaluation of thyroid nodules. However, approximately 5-20% of thyroid nodules are considered indeterminate or suspicious cases that do not meet clinical standards. The B-RAF(V600E) mutation has been reported in FNA specimens. We conducted a systematic review to evaluate the diagnostic value of testing for B-RAF(V600E) in thyroid nodules that are difficult to diagnose by FNA. A systematic literature search was performed from January 1, 2002 to June 30, 2012. Articles were obtained by searching two electronic databases (MEDLINE and EMBASE), hand searching selected journals, and contacting authors. Article quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. Sensitivity, specificity, and other measures of accuracy were pooled using random effects models. Summary receiver operating characteristic (SROC) curves were used to summarize overall diagnostic accuracy. A total of 16 studies incorporating 1131 patients were included in a meta-analysis on diagnostic accuracy of B-RAF(V600E) tests. Pooled sensitivity was 0.60 (95% confidence interval [CI]: 0.556-0.634), pooled specificity was 0.99 (95% CI 0.976-0.997), and the area under the curve of the SROC curve was 0.8376. Q index value was 0.7696. Our data suggest a potentially useful adjunct to evaluating thyroid nodules that are difficult to diagnose. The B-RAF(V600E) test has a high positive predictive value and could help clinicians formulate a more individualized treatment schedule. When supplemented with other noninvasive test methods, the B-RAF(V600E) test could be a powerful adjunct with extensive clinical applications.
More Related Videos
10:19Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
10:16Employing Digital Droplet PCR to Detect BRAF V600E Mutations in Formalin-fixed Paraffin-embedded Reference Standard Cell Lines
Published on: October 8, 2015