Flow dynamics using high-frequency jet ventilation in a model of bronchopleural fistula
M J Wood1, E S Lin, J P Thompson
1Department of Cardiovascular Sciences, University of Leicester and University Hospitals of Leicester NHS Trust, Leicester, UK.
Background:
Positive pressure ventilation in patients with a bronchopleural fistula (BPF) is associated with variable, unpredictable gas leaks that can impair gas exchange. The optimum settings for high-frequency jet ventilation in this scenario are unclear. We investigated flow dynamics with BPFs of 2 and 10 mm, at various positions and with different jet ventilator settings in a bench-top model.
Methods:
A 2 or 10 mm length fistula was created at proximal, middle, or distal sites in standard artificial ventilator 'test' lungs and cadaveric porcine lungs. The effects of alterations in frequency, applied pressure, and on entrained, expired, and leak volumes were determined using gauge and differential pressure sensors.
Results:
Entrained, delivered, and leak volumes were affected markedly by ventilator settings, particularly frequency: leaks were much greater at frequencies <100 min(-1). The leak/expired volume ratio varied between 0% and 92%. Leak and entrained volumes increased progressively with more proximally situated fistulae, whereas the measured expired volume decreased. Leak volumes with a 2 mm fistula were approximately half that of a 10 mm fistula across all ventilator frequencies. All volumes increased with increased driving pressure. The optimum injection time varied depending on BPF position and the accepted compromise between leak and expired volumes. Entrained volume contributed up to 50% of the total tidal volume.
Conclusions:
These data suggest that gas leak will be minimized and ventilator volumes maintained during jet ventilation using frequencies >200 min(-1) and lower driving pressures, but confirmatory clinical studies are required. Values displayed by the jet ventilator are unreliable.
Related Concept Videos
Pneumothorax II: Pathophysiology
Free Jet
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Application of Integration: Problem Solving
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...