Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

874
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
874
Method of Superposition01:20

Method of Superposition

2.2K
The method of superposition is a crucial technique in structural engineering, used to analyze the effect of multiple loads on beams. This approach involves calculating the deflection and slope for each load on a beam separately, and then summing these effects to determine the overall impact. It is applicable only when the beam material remains within its elastic limit, ensuring that deformations are linearly elastic.
When applying the method of superposition, each type of load—whether...
2.2K
Method of Joints01:30

Method of Joints

2.0K
The method of joints is a commonly used technique to analyze the forces in structural trusses. The method is based on the principle of equilibrium, which assumes that the truss members are connected by frictionless pins. The forces at each joint can be determined by considering the equilibrium of the forces acting on that joint.
Since plane truss members are in the same plane, each joint is subjected to a coplanar and concurrent force system. To apply the method of joints, the first step is to...
2.0K
Fixing Double-strand Breaks02:04

Fixing Double-strand Breaks

12.1K
The double-stranded structure of DNA has two major advantages. First, it serves as a safe repository of genetic information where one strand serves as the back-up in case the other strand is damaged. Second, the double-helical structure can be wrapped around proteins called histones to form nucleosomes, which can then be tightly wound to form chromosomes. This way, DNA chains up to 2 inches long can be contained within microscopic structures in a cell. A double-stranded break not only damages...
12.1K
Fixing Double-strand Breaks02:04

Fixing Double-strand Breaks

3.5K
3.5K
Method of Joints: Problem Solving II01:30

Method of Joints: Problem Solving II

1.7K
Consider a truss structure with frictionless joints fixed to a wall and roller support. If a force of 150 N is applied to joint A, the forces in each member of the truss can be determined using the method of joints.
1.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

First Measurement of η Meson Production in Neutrino Interactions on Argon with MicroBooNE.

Physical review letters·2024
Same author

Commentary on the published position statement regarding the pathogenesis of fetal basal ganglia- thalamic hypoxic-ischaemic injury.

South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde·2024
Same author

First Double-Differential Measurement of Kinematic Imbalance in Neutrino Interactions with the MicroBooNE Detector.

Physical review letters·2023
Same author

First Measurement of Quasielastic Λ Baryon Production in Muon Antineutrino Interactions in the MicroBooNE Detector.

Physical review letters·2023
Same author

First Constraints on Light Sterile Neutrino Oscillations from Combined Appearance and Disappearance Searches with the MicroBooNE Detector.

Physical review letters·2023
Same author

Search for an Excess of Electron Neutrino Interactions in MicroBooNE Using Multiple Final-State Topologies.

Physical review letters·2022

Related Experiment Video

Updated: May 6, 2026

Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears
05:25

Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears

Published on: January 23, 2026

674

A new "double tie-over method" and its applications.

M Inaba1, J Anthony, T Ezaki

  • 1, Tokyo, Japan.

Aesthetic Plastic Surgery
|November 1, 2013
PubMed
Summary
This summary is machine-generated.

A new double tie-over dressing technique improves skin grafting outcomes by reducing dressing size and preventing graft displacement. This method offers a safe and effective alternative for various skin graft applications.

More Related Videos

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
08:27

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel

Published on: May 23, 2025

1.3K
A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
06:41

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears

Published on: January 13, 2026

390

Related Experiment Videos

Last Updated: May 6, 2026

Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears
05:25

Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears

Published on: January 23, 2026

674
Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
08:27

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel

Published on: May 23, 2025

1.3K
A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
06:41

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears

Published on: January 13, 2026

390

Area of Science:

  • Dermatology
  • Surgical Innovation

Background:

  • Traditional tie-over dressings for skin grafts are bulky and prone to graft displacement.
  • Graft displacement can lead to complications such as hematoma and secondary necrosis, particularly in sensitive areas like the axilla and anus.

Purpose of the Study:

  • To introduce and evaluate a novel "double tie-over type dressing" (double tie-over method).
  • To assess the efficacy of this new method in preventing complications associated with skin grafting.

Main Methods:

  • The double tie-over method was developed for postoperative application following procedures like subcutaneous shaving for hyperhidrosis and hircismus.
  • The technique was applied to skin grafts in various anatomical locations.

Main Results:

  • The new dressing is significantly smaller in volume compared to traditional methods.
  • The double tie-over method effectively prevents grafted skin from shifting during patient movement.
  • Excellent and favorable results were observed across diverse skin graft applications.

Conclusions:

  • The double tie-over method represents an easy and safe advancement in skin graft dressing techniques.
  • This innovative approach enhances graft stability and reduces the risk of postoperative complications.
  • The method is versatile and suitable for a wide range of skin grafting procedures.