Related Experiment Video
Updated: May 6, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
[Evaluation and implementation of in vivo transit dosimetry with an electronic portal imaging device]
P Boissard1, P François, V Rousseau
1Service de physique médicale, institut Curie, 26, rue d'Ulm, 75005 Paris, France.
Purpose:
In vivo dosimetry is now widely recommended to avoid major treatment error. Transit dosimetry using portal imagers allows fast and accurate in vivo dose verifications. Several teams have published clinical studies but no recommendation has been proposed to define tolerance levels and validation criteria. This study proposes a simple methodology to assess the overall standard deviation of transit dosimetry and was applied to our transit dosimetry method.
Material And Methods:
In a first step, the uncertainties due to the dose reconstruction method are evaluated. Their estimation is based on a set of geometries, representative of clinical situations for which 45 points of measurement have been defined. In a second step, we studied the variations of our method in clinical situations. During the treatment session of the patient, the dose was reconstructed and the differences between reconstructed dose and prescribed dose were used to define a realistic tolerance level, adapted to the clinical routine. Then, a methodology is proposed to determine if the transit dosimetry method, with the defined tolerance level allows detecting significant treatment errors (>5% of the prescribed dose). RESULTS -
Conclusion:
Applying this methodology we concluded that a tolerance level of 6.5% (k=2) can be associated with our method. With this value, it is demonstrated that in many cases differences of 5% (or less) on the prescribed dose can be detected. This study demonstrates clearly that in vivo transit dosimetry is not able to detect all the treatment errors but remains an ultimate and efficient tool in many situations.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...