Related Experiment Video
Updated: May 6, 2026

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Double-bed-type extraction needle packed with activated-carbon-based sorbents for very volatile organic compounds
Ikuo Ueta1, Emi Liana Samsudin, Ayako Mizuguchi
1Department of Applied Chemistry, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Abstract:
A novel needle-type sample preparation device was developed for the determination of very volatile organic compounds (VVOCs) in gaseous samples by gas chromatography-mass spectrometry (GC-MS). Two types of activated-carbon-based sorbents, Carbopack X and a carbon molecular sieve (CMS), were investigated as the extraction medium. A double-bed-type extraction needle showed successful extraction and desorption performance for all investigated VVOCs, including acetaldehyde, isoprene, pentane, acetone, and ethanol. Sensitive and reliable determination of VVOCs was achieved by systematically optimizing several desorption conditions. In addition, the effects of sample humidity on the extraction and desorption of analytes were investigated with the needle-type extraction devices. Only the CMS packed extraction needle was adversely affected by sample humidity during the desorption process; on the other hand the double-bed-type extraction needle was unaffected by sample humidity. Finally, the developed double-bed-type extraction needle was successfully applied to the analysis of breath VVOCs of healthy subjects.
More Related Videos
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Volatilization
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

