Related Experiment Video
Updated: May 6, 2026

Spatial Measurements of Perfusion, Interstitial Fluid Pressure and Liposomes Accumulation in Solid Tumors
Published on: August 18, 2016
Diagnostic value of CT perfusion imaging for parotid neoplasms
1Department of Radiology, the First Affiliated Hospital of Dalian Medical University, Dalian, China.
Objectives:
To assess the value of CT perfusion imaging in the differentiation of different histological categorization of benign tumours from malignant tumours in patients with parotid neoplasms.
Methods:
CT perfusion was successfully performed in 62 patients with parotid neoplasms whose diagnoses were confirmed by surgery or biopsy. The software generated a tissue time-density curve (TDC) and measured blood volume, blood flow, mean transit time and capillary permeability surface product. One-way ANOVA and receiver operating characteristic curves were used to analyse the difference and diagnostic efficacies of all perfusion data between each one of the benign tumours and malignancies. Statistical significance was assigned at the 5% level.
Results:
Pleomorphic adenomas mainly had a gradually ascending TDC. Warthin tumours showed a fast ascent followed by a fast descent. The TDC of basal cell adenomas had a fast ascension followed by a plateau, then a gradual descent. Malignant tumours mainly showed a rapidly ascending curve with a stable plateau. Significant differences were observed in blood flow, blood volume and mean transit time between pleomorphic adenomas and malignant tumours (p < 0.05) as well as in blood flow and blood volume between the Warthin tumours, the basal cell adenomas and the malignant tumours (p < 0.05). Differences in permeability surface between the basal cell adenomas and malignant tumours were significant (p < 0.01).
Conclusion:
CT perfusion of parotid gland could provide TDC and perfusion data, which were useful in the differentiation of different histological benign tumours and malignant tumours in the parotid gland.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...