Filtered backprojection reconstruction and redundancy in Compton camera imaging
Related Experiment Video
Updated: May 6, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Abstract:
During the acquisition process with the Compton gamma-camera, integrals of the intensity distribution of the source on conical surfaces are measured. They represent the Compton projections of the intensity. The inversion of the Compton transform reposes on a particular Fourier-Slice theorem. This paper proposes a filtered backprojection algorithm for image reconstruction from planar Compton camera data. We show how different projections are related together and how they may be combined in the tomographical reconstruction step. Considering a simulated Compton imaging system, we conclude that the proposed method yields accurate reconstructed images for simple sources. An elongation of the source in the direction orthogonal to the camera may be observed and is to be related to the truncation of the projections induced by the finite extent of the device. This phenomenon was previously observed with other reconstruction methods, e.g., iterative maximum likelihood expectation maximization. The redundancy of the Compton transform is thus an important feature for the reduction of noise in Compton images, since the ideal assumptions of infinite width and observation time are never met in practice. We show that a selection operated on the set of data allows to partially get around projection truncation, at the expense of an enhancement of the noise in the images.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Imaging
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...