Purpose:
The demand for arthroplasty is rapidly growing as a result of the ageing of the population. Although complications such as heterotrophic ossification, fracture and dislocation are relatively rare, differentiating aseptic loosening, the most common complication of arthroplasty from infection, is a major challenge for clinicians. Radionuclide imaging is currently the imaging modality of choice since it is not affected by orthopaedic hardware. Whereas FDG PET/CT imaging has been widely used in periprosthetic infection, it cannot discriminate aseptic from septic inflammation. In this study we aimed to evaluate the role of FDG PET/CT and FDG-labelled leucocyte PET/CT in the diagnosis of periprosthetic infection.
Methods:
Of 54 patients with painful joint arthroplasty who were imaged by FDG PET/CT for diagnosis of periprosthetic infection examined, 46 (36 women, 10 men; mean age 61.04 ± 12.2 years, range 32-89 years) with 54 painful joint prostheses (19 hip, 35 knee) with grade 2 (above liver uptake) FDG accumulation on FDG PET/CT were included in the study and these 46 patients also underwent FDG-labelled leucocyte PET/CT. Final diagnoses were made by histopathological-microbiological culture or clinical follow-up.
Results:
The final diagnosis showed infection in 15 (28%) and aseptic loosening in 39 (72%) of the 54 prostheses. FDG PET/CT was found to have a positive predictive value of 28% (15/54). Since patients with no FDG uptake on FDG PET/CT were excluded from the study, the sensitivity, specificity, negative predictive value and accuracy could not be calculated. The sensitivity, specificity, and positive and negative predictive values of FDG-labelled leucocyte PET/CT were 93.3% (14/15), 97.4% (38/39), 93.3% and 97.4%, respectively.
Conclusion:
Since FDG is not specific to infection, the specificity of FDG PET/CT was very low. FDG-labelled leucocyte PET/CT with its high specificity may be a useful method and better than labelled leucocyte scintigraphy in periprosthetic infection imaging.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
17:13Non-invasive Imaging of Acute Allograft Rejection after Rat Renal Transplantation Using 18F-FDG PET
Published on: April 28, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...