Abstract:
The infrared radiation emitted from the surface of inflorescences of 12 aroid species was monitored with an infrared camera, capable of 0.1°C resolution, and the data were converted to temperature values by means of temperature reference standards. Images representing surface temperatures were obtained forAmorphophallus bulbifer Blume,A. campanulatus Blume,A. forbesii Engl. et Gehrm.,A. rivieri Dur.,Philodendron selloum Koch,Monstera deliciosa Liebm.,Dracunculus vulgaris Schott,Arum italicum Mill.,A. dioscoridis Sibth.,A. creticum Boiss et Heldr.,Caladium sp., andRemusatia vivipara Schott. These images were different among species with respect to temperature, duration of detectable heat development, and organ type (male and female flowers, spathe and appendix) found to be thermogenic. All these species, however, exhibited three common characteristics: 1) production of heat by the male flowers; 2) pollen-shedding immediately after heat production had ceased; and 3) when male flowers were some distance away from female flowers along the spadix, heat was not detected in female flowers. Heat emission was associated with the alternative, cyanide-insensitive pathway that was fully operative.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Thermosensation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
IR Spectrometers