Effect of high-performance liquid chromatography mobile phase components on sensitivity in negative atmospheric
1Department of Drug Metabolism and Pharmacokinetics, SmithKline Beecham Pharmaceuticals, King of Prussia, Pennsylvania, USA.
Abstract:
We have investigated the effect of several common buffers (10-mM formic acid, 10-mM ammonium acetate, and 100-mM ammonium acetate) on the ionization of a series of model compounds that are amenable to negative atmospheric pressure chemical ionization to determine the extent of ionization quenching that can occur. In addition, we have compared the sensitivity of these standard mobile phases to a mobile phase that does not contain an acidic buffer component, but rather a base (N-methylmorpholine). The results showed that, as expected, the sensitivity for the test analytes was greatest in the mobile phase that lacked acidic components. In general, ionization of analytes that contained a single, more weakly acidic functional group was inhibited to a greater degree by more strongly acidic buffer components. In some cases, ionization was quenched completely by acidic buffer components, Ionization of compounds that were more strongly acidic was quite good in all mobile phases tested. Differences in the ionization efficiencies of the analytes in each mobile phase were correlated with the gas-phase reagent ions present. As a point of reference, each of the analytes also was analyzed in the positive ion mode and the signal intensities were compared to those obtained in the negative ion mode. In addition, the utility of mobile phases that contained N-methylmorpholine for chromatographic separations was demonstrated.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences