Are standard intra-abdominal pressure values different during pregnancy?

Florent Fuchs1, Marie Bruyere, Marie-Victoire Senat

  • 1Department of Obstetrics and Gynecology. Hôpital Bicêtre, Assistance Publique Hôpitaux de Paris, Le Kremlin-Bicêtre, France ; Inserm, Centre for research in Epidemiology and Population Health, Unit 1018, Reproduction and child development, Villejuif, France ; Paris-Sud University, Unit 1018, Villejuif, France.

Plos One
|November 9, 2013
PubMed
Summary

Intra-abdominal pressure (IAP) is higher before cesarean delivery than after. This finding is crucial for managing potential organ dysfunction following cesarean birth.

Related Concept Videos

Pressure Relationships in Thoracic Cavity01:24

Pressure Relationships in Thoracic Cavity

Breathing, otherwise known as pulmonary ventilation, is the process of air movement into and out of the lungs. The main mechanisms propelling pulmonary ventilation are atmospheric pressure (Patm), intra-pulmonary (Ppul ) or intra-alveolar pressure (Palv) within the alveoli, and intrapleural pressure (Pip) within the pleural cavity.
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
8.7K
Pulmonary Ventilation: Inhalation01:24

Pulmonary Ventilation: Inhalation

Pulmonary ventilation is a vital process that ensures the exchange of oxygen and carbon dioxide in the lungs. It refers to the movement of air into and out of the lungs, enabling the body to obtain oxygen and remove waste carbon dioxide. In this article, we will explore the intricacies of pulmonary ventilation, including its underlying principles, mechanisms, and the interplay of pressures within the respiratory system.
Boyle's law becomes particularly pertinent when examining respiratory...
11.1K
Special considerations while measuring blood pressure01:28

Special considerations while measuring blood pressure

When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
1.5K
Appendicitis-I: Introduction01:22

Appendicitis-I: Introduction

The appendix, a small, narrow, blind tube extending from the inferior part of the cecum, is widely regarded as a vestigial organ, having lost much of its original function through evolution. Despite its diminished role, the appendix can become inflamed, a condition known as appendicitis.
Etiology: Appendicitis can arise from various causes, primarily rooted in the obstruction of the appendix lumen. Factors contributing to this obstruction include fecal accumulation, lymphoid hyperplasia and, in...
4.5K