Optimization of the HS-SPME-GC-IT/MS method using a central composite design for volatile carbonyl compounds
Nathalie Moreira1, Sónia Meireles, Tiago Brandão
1REQUIMTE/Laboratório de Toxicologia, Departamento de Ciências Biológicas, Faculdade de Farmácia, Universidade do Porto, Rua Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal; CBQF/Centro de Biotecnologia e Química Fina, Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Rua Dr. António Bernardino Almeida, 4200-072 Porto, Portugal.
Abstract:
An automated headspace solid-phase microextraction (HS-SPME) combined with gas chromatography and ion trap mass spectrometry detection (GC-IT/MS) was developed in order to quantify a large number of carbonyl compounds in beers. Carbonyl compounds were previously derivatized with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA). Volatile carbonyl compounds associated with staling beer aroma includes alkanals, alkenals, alkadienals, dicarbonyl compounds, Strecker aldehydes, ketones and furans. The HS-SPME was performed using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber. The procedures were optimized for HS-SPME pre-incubation temperature and time, extraction temperature and time, and PFBHA addition. A central composite design was used in the optimization of extraction conditions and PFBHA addition. The volatile compounds showed optimal extraction incubating 5 ml of beer with 700 mg l(-1) of PFBHA for 7 min and extracted for more 20 min at 45 °C. The method was validated with regard to the linearity, repeatability, inter and intra-day precision and accuracy. The method achieved detection limits ranging from 0.003 to 0.510 µg l(-1), except for furans (1.54-3.44 µg l(-1)). The quantification limits varied from 0.010 to 1.55 µg l(-1), except for 2-furfural (4.68 µg l(-1)), 5-methyl-2-furfural (5.82 µg l(-1)) and 5-hyfroxymethylfurfural (10.4 µg l(-1)). Repeatability values of all compounds were lower than 17%. The method accuracy was satisfactory with recoveries ranging from 88% to 114%. The validated method showed to be suitable for a fast and reliable determination of main carbonyl compounds in beers.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
