Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Possibilities of new generation columns packed with 1.3μm core-shell particles in gradient elution mode
Szabolcs Fekete1, Davy Guillarme
1School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland.
Abstract:
The aim of this work was to evaluate the practical possibilities in gradient elution mode of a column packed with 1.3μm core-shell particles recently released on the market. For this purpose, two types of analytes possessing different diffusion coefficients were selected (small molecule and peptide). It appears that the new 1.3μm material was particularly well suited for fast separations, compared to other existing core-shell particle dimensions in gradient mode. The new material systematically outperforms the other existing ones for peak capacity up to 300 for small molecules and 700 (corresponding to t0=15min) for peptides. Based on these cut-off values, the advantage of column packed with 1.3μm was much more obvious for peptides vs. small molecules analysis. Further improvements in terms of column mechanical stability and system upper pressure capability could expand the limits of separation speed and efficiency to a different level. Again, because of the current pressure limitation and low permeability, a column length of more than 5-8cm is never desired for small molecules analysis in gradient elution. On the contrary, longer columns were useful for peptide analysis. As example, a column of 28cm packed with 1.3μm particles provides a peak capacity of 1000 in the case of peptides analysis. All the predicted values were experimentally confirmed using a standardized extract of Ginkgo biloba and a tryptic digest of a monoclonal antibody (Panitumumab). For the plant extract, the better performance was always achieved with a 5cm long column (P=267 and 268 for the 5 and 15cm, respectively, using a gradient time of 10 and 40min, respectively). Finally, in the case of peptide mapping, a 15cm long column packed with 1.3μm particles was the best choice (P=176 and 311 for the 5 and 15cm, respectively, using a gradient time of 10 and 40min, respectively).
Related Concept Videos
Principles Of Column Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Ion-Exchange Chromatography