Related Experiment Video
Updated: May 6, 2026

A Method to Estimate Cadaveric Femur Cortical Strains During Fracture Testing Using Digital Image Correlation
Published on: September 14, 2017
The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during
F Gillard1, R Boardman, M Mavrogordato
1Bioengineering Science Research Group, University of Southampton, Southampton SO17 1BJ, UK.
Abstract:
Digital Volume Correlation (DVC) has been emerged recently as an innovative approach to full volume (i.e. internal) displacement and strain field measurement in materials and structures, particularly in conjunction with high resolution X-ray computed tomography (CT). As a relatively novel technique certain aspects of precision, accuracy and the breadth of application are yet to be fully established. This study has applied DVC to volume images of porcine trabecular bone assessing the effect of noise and sub-volume size on strain measurement. Strain resolutions ranging between 70 and 800με were obtained for the optimum sub-volume size of 64 voxels with a 50% overlap for metrological studies conducted. These values allowed the mechanical behaviour of porcine trabecular bone during compression to be investigated. During compression a crushed layer formed adjacent to the boundary plate which increased in thickness as the specimen was further deformed. The structure of the crushed layer was altered to such an extent that it confounded the correlation method. While investigating this factor, it was found that for reliable strain calculations a correlation coefficient of 0.90 or above was required between the sub-volumes in the reference and the deformed volumes. Good agreements between the results and published bone strain failures were obtained. Using the full field strain measurements, Poisson's ratio was identified for each compression step using a dedicated inverse method called the virtual fields method (VFM). It was found that for a given region outside of the crushed zone the Poisson ratio decreased from 0.32 to 0.21 between the first and the final compression steps, which was hypothesised to be due to the bone geometry and its resulting deformation behaviour. This study demonstrates that volumetric strain measurement can be obtained successfully using DVC, making it a useful tool for quantitatively investigating the micro-mechanical behaviour of macroscale bone specimens.
Related Concept Videos
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Gross Anatomy of Bone
The diaphysis is the tubular shaft that runs between the proximal and distal ends of the bone. The walls of the diaphysis are composed of dense and hard compact bone made of numerous osteons — the functional unit of the compact bone. The hollow region in the diaphysis is called the medullary cavity, which harbors the bone marrow. In infants and children, this marrow cavity is filled with red marrow, whereas in...

