Leaf Spray Mass Spectrometry: A Rapid Ambient Ionization Technique to Directly Assess Metabolites from Plant Tissues
Published on: June 21, 2018
Comparative study of different thermospray interfaces with carbamate pesticides: Influence of the ion source geometry
1Department of Analytical Chemistry, Fraunhofer Institute for Toxicology and Aerosol Research, Hannover, Germany.
Abstract:
Sixteen carbamate pesticides that belong to four chemical classes (oxime-N-methylcarbamates, aryl N-methylcarbamates, N-phenylcarbamates, and methyl esters of substituted carbamic acids) were investigated via three different commercially available thermospray interfaces and ion sources that exhibit wide differences in source geometry. Comparisons were made between the three interfaces with respect to ion formation and sensitivity of detection. Experimental parameters were standardized to obtain comparable experimental conditions. Very similar mass spectra for most carbamates were obtained that illustrate independence from the geometry of the ionization and desolvation chambers of the interfaces. These findings are in sharp contrast to several literature reports. However, thermally labile carbamates gave unsatisfactory results with regard to spectral compatibility between the interfaces. Such differences were due to thermally assisted hydrolysis reactions that occur in the vaporizer probe prior to ionization and reflect differences in the vaporizer designs. The study proves conclusively that comparable spectra can be obtained under thermospray with different interfaces and mass spectrometers.
More Related Videos
08:54Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry SESI-MS
Published on: June 8, 2011
10:35Study on the Metabolism of Six Systemic Insecticides in a Newly Established Cell Suspension Culture Derived from Tea Camellia Sinensis L. Leaves
Published on: June 15, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...