Related Experiment Video
Updated: May 6, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
New approach to quantification of molecularly targeted radiotracer uptake from hybrid cardiac SPECT/CT: methodology
Shimin Li1, Albert J Sinusas, Lawrence W Dobrucki
1Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut.
Unlabelled:
Quantification of molecularly targeted radiotracer uptake in the myocardium from SPECT remains challenging in part due to potentially low levels of focal tracer uptake of presently available molecularly targeted agents and further degradation of cardiac SPECT by extracardiac radioactivity and partial-volume effect. The purpose of this study was to derive and validate a new SPECT quantification method for assessments of absolute radiotracer uptake in the myocardium.
Methods:
The method was integrated with a hybrid micro-SPECT/CT imaging protocol to calculate radiotracer uptake of a molecularly targeted agent in the ischemic myocardium. CT coregistered with SPECT was used to identify the position and orientation of the left ventricle. Corrections for extracardiac activity and partial-volume errors were performed via a heuristic method derived with a total count sampling scheme. Myocardial radiotracer uptake was quantified from SPECT using an external point source as a known reference. Methods were validated using an ischemic rat model injected with a (99m)Tc-labeled SPECT radiotracer targeted at αvβ3 integrin. SPECT-quantified myocardial radiotracer uptake was compared with postmortem myocardial tissue well-counted radioactivity.
Results:
Initial correlation between SPECT-quantified and well-counted radioactivity was fair (R(2) = 0.19, y = 0.50x + 0.05, P = 0.06) when no correction was applied to SPECT quantification. Correlation was significantly improved with tissue weight correction (R(2) = 0.84, y = 1.82x - 0.01, P < 0.001), and a trend toward the improvement of correlation was observed with extracardiac activity correction (R(2) = 0.85, y = 1.54x - 0.01, P < 0.001) and partial-volume correction (R(2) = 0.86, y = 1.68x - 0.01, P < 0.001). Reproducibility of the SPECT quantification was excellent, either with no correction (R(2) = 0.99, y = 1.00x + 0.00, P < 0.001) or with all corrections (R(2) = 1.00, y = 1.00x - 0.00, P < 0.001).
Conclusion:
Corrections for the myocardial tissue weight, extracardiac activity, and partial-volume errors are crucial for precise assessments of myocardial radiotracer uptake using micro-SPECT/CT. The quantitative SPECT/CT approach developed provides a reasonable and reproducible in vivo estimation of absolute radiotracer uptake in a model of myocardial injury and should permit quantitative serial monitoring of subtle changes in the myocardial uptake of targeted radiotracers.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT