Related Experiment Video
Updated: May 6, 2026

Subcostal Specimen Removal in Completely Portal Robotic Lobectomy
Published on: April 19, 2024
Trocar site hernia on an 8-mm port following robotic-assisted hysterectomy
Gokhan Sami Kilic1, Tevfik Berk Bildaci2, Omer Lutfi Tapisiz1
1Department of Obstetrics and Gynecology, University of Texas Medical Branch, Galveston, TX, USA.
Abstract:
The increasing use of laparoscopy has resulted in added complications specific to the laparoscopic approach, such as trocar site hernia (TSH), which is an uncommon but well-recognized problem for both regular laparoscopic and robotic-assisted laparoscopic procedures. We describe an extremely rare case of TSH at an 8-mm port site occurring a relatively short time after surgery in a 53-year-old patient undergoing robotic-assisted laparoscopic hysterectomy for benign reasons. Additionally, this report attempts to explain the possible etiological factors relating to TSH following robotic-assisted surgery. According to our case report, a defect in the 8-mm port that may lead to hernia is one possible explanation, and closure of the 8-mm trocar sites' fascia may be a safer approach during robotic-assisted surgery. Additional reports are needed to accurately determine the frequency of occurrence and importance of this complication.