Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
A pharmacokinetic study of 48-hour sevoflurane inhalation using a disposable delivery system (AnaConDa®) in ICU
S Perbet1, D Bourdeaux, V Sautou
1CHU Clermont-Ferrand, Intensive Care Unit, Department of Anesthesiology and Critical Care Medicine, CHU Estaing, Clermont-Ferrand, France - sperbet@chu-clermontferrand.fr.
Background:
Little is known regarding sevoflurane kinetics and toxicity during long-term sedation of intensive care unit (ICU) patients using the AnaConDa® system. The objective of the present study was to establish a pharmacokinetic description of 48-h sevoflurane administration, and to estimate plasma concentrations of metabolites.
Methods:
Forty-eight hour sedation with sevoflurane vaporized via an AnaConDa® device, with an end-tidal concentration objective of 1.5% (v/v), was initiated in 12 non-obese patients who did not have hepatic or renal failure but who required sedation for more than 48 h in our ICU. Plasma sevoflurane, hexafluoroisopropanol, and fluoride concentrations were determined over this time period and pharmacokinetic analysis was performed.
Results:
The mean plasma concentration of sevoflurane was 76 mg/L at 24 h and 70 mg/L at 48 h. Wash-out of plasma sevoflurane correlated with a rapid decrease in the mean end-tidal sevoflurane level. The mean free plasma fraction of hexafluoroisopropanol never exceeded 8 mg/mL. The mean fluoride concentration was 0.8 µmol/L on day 0, 51.7 µmol/L on day 1, and 68.1 µmol/L on day 2 (P<0.0001). The distribution volume was 53 L, the elimination constant 2.9 h-1, the transfer constant from compartment 1 to compartment 2 (K1-2) 1.2 h-1, the K2-1 0.26 h-1, the half-life of elimination 3.78 h, and the total clearance 156 L/h.
Conclusion:
Following 48 hours of sedation using sevoflurane inhalation administered using an AnaConDa® delivery device, sevoflurane washout was rapid. Plasma fluoride levels accumulated over the study period without apparent nephrotoxicity.
More Related Videos
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Inhalational Anesthetics: Overview
Parenteral Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...