Related Experiment Video
Updated: May 6, 2026

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Changes in thenar muscle tissue oxygen saturation assessed by near-infrared spectroscopy during weaning from
M Poriazi1, M Kontogiorgi, E Angelopoulos
1First Department of Critical Care, Medical School University of Athens, Evangelismos Hospital, Athens, Greece - chroutsi@hotmail.com.
Background:
Tissue oxygen saturation (StO₂) measured by near-infrared spectroscopy (NIRS) has been used to provide information on local tissue oxygenation in different clinical settings. This study aims to determine the effect of weaning from mechanical ventilation on thenar muscle StO₂.
Methods:
In consecutive critically ill mechanically ventilated patients, StO₂ at the thenar eminence, along with a vascular occlusion test (VOT), were measured by NIRS, on mechanical ventilation and during a 2-hour T-piece spontaneous breathing trial (SBT). Hemodynamic, gas exchange and respiratory variables were recorded.
Results:
Forty-four patients were included in this study, 25 tolerated the SBT and 19 failed. On mechanical ventilation, no differences in any measured variable were observed between patients who succeeded or failed. Two minutes after SBT start, StO₂ was decreased in patients who failed whereas it did not change in patients who succeeded (P<0.001). For all data, 2 minutes after the start of SBT, StO₂ significantly correlated with SaO₂ (r=0.32, P=0.037) and with the respiratory frequency/tidal volume (f/VT) index (r=-0.34, P=0.023). VOT-derived StO₂ downslope and StO2 upslope did not change significantly along the SBT test. The maximum StO₂ value, its ratio to minimum StO2, and the post-VOT StO₂ value decreased significantly in patients who failed whereas no change was found in those who succeeded the SBT (P=0.003, P=0.025 and P<0.001 respectively). StO₂ and f/VT at the second minute of SBT yielded a receiver operator characteristics curve area value of 0.77 and 0.80, P=0.002, respectively, in detecting the SBT outcome.
Conclusion:
SBT failure was associated with a significant impairment of thenar muscle StO₂. A decrease of StO₂ at 2 minutes after disconnection from the ventilator was associated with SBT failure. Further validation is warranted.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.