Related Experiment Video
Updated: May 5, 2026

08:22
Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
6.5K
Novel tandem quadrupole-acceleration-deceleration mass spectrometer for neutralization-reionization studies
1Department of Chemistry, University of Washington, BG-10, 98195, Seattle, WA.
Journal of the American Society for Mass Spectrometry
|November 16, 2013
Summary
A novel quadrupole-acceleration lens-deceleration-lens-quadrupole mass spectrometer was developed for neutralization-reionization studies. This instrument achieves high ion transmission and unit mass resolution for aromatic compounds.
Area of Science:
- Analytical Chemistry
- Mass Spectrometry
- Physical Chemistry
Background:
- Neutralization-reionization mass spectrometry (NRMS) is a powerful technique for studying ion structures and reactions.
- Existing instruments may have limitations in ion transmission or resolution for specific applications.
Purpose of the Study:
- To describe a new tandem mass spectrometer with a quadrupole-acceleration lens-deceleration-lens-quadrupole (QADQ) configuration.
- To evaluate the performance of the QADQ instrument for neutralization-reionization studies.
Main Methods:
- The instrument comprises two 2000-u quadrupole mass analyzers (MS-I and MS-II) separated by an acceleration lens, three collision cells, and a deceleration lens/energy filter.
- High total ion transmission was achieved for 5-9-keV ions.
- The system demonstrated unit mass resolution in neutralization-reionization mass spectra.
Main Results:
- The QADQ mass spectrometer successfully performed neutralization-reionization studies.
- High ion transmission was observed across a range of ion energies.
- Unit mass resolution was achieved for the analysis of aromatic compounds.
Conclusions:
- The developed QADQ tandem mass spectrometer is suitable for neutralization-reionization studies.
- The instrument offers high performance in terms of ion transmission and mass resolution.
- Further studies can utilize this instrument for detailed structural analysis of ions.
Related Concept Videos
Tandem Mass Spectrometry
3.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K
Mass Analyzers: Common Types
2.0K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
2.0K
Mass Spectrometers
9.6K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
9.6K
Mass Analyzers: Overview
2.1K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.1K
Peptide Identification Using Tandem Mass Spectrometry
6.2K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.2K
Mass Spectrum: Interpretation
4.1K
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
4.1K