Purpose:
The purpose of this study is to identify risk factors related to the development of subsequent fractures after vertebroplasty.
Method:
A retrospective study was conducted to review 175 patients with a 1-year follow-up who underwent vertebroplasty for first-time and single-level osteoporotic vertebral fractures. Subsequent fractures were diagnosed as recurrent intractable back pain, post-operatively correlated with MR image. Clinical parameters, such as age, gender, baseline VAS-score, lumbar bone mineral density (BMD) T-score, history of use of steroids, bisphosphonate therapy, symptom-free interval, the amount of bone cement injected, vacuum clefts, leakage of cement into the disk space, treated level and the changes of spinal geometry were recorded.
Results:
During the follow-up period, subsequent fractures developed in 37 (21.1 %) of 175 patients. Significant differences (P < 0.05) were found between the patients with subsequent fractures and the patients without subsequent fractures in regard to their BMD T-score, and treated vertebrae location. Average BMD T-score was -3.4 ± 1.5 in patients with subsequent fractures and -2.9 ± 1.6 in patients without subsequent fractures. The percentage of subsequent fractures was 13.9 % (10 of 72) for treated vertebrae located in non-thoracolumbar junction, and 26.2 % (27 of 103) in the thoracolumbar junction.
Conclusion:
The most important risk factors affecting subsequent fractures after vertebroplasty were osteoporosis and treated level at the thoracolumbar junction.