X-ray microtomography of biological tissues using laboratory and synchrotron sources
J C Elliott1, D K Bowen, S D Dover
1Department of Biochemistry, The London Hospital Medical College, Turner Street, EI 2AD, London, UK.
Abstract:
X-ray microradiography is a well established technique for the study of biological structures in which the projected absorption is measured, usually with photographic film or resist. If scanning X-ray microradiography with a 15-μm beam, 2-D scanning, and photon counting is used, more accurate results can be obtained and real-time experiments undertaken. Addition of a rotation axis allows computerized axial tomography to be done at a resolution of 15 μm. This technique overcomes the inherent difficulty of microradiography that all detail perpendicular to the plane of the specimen is superimposed. This method has been applied to the study of the 3-D mineral distribution in a 0.8×0.8 mm column of human cortical bone with a laboratory X-ray source. Calculation of the wavelength dependence of the linear absorption coefficient for liver and bone shows that, for a choice of wavelength in the range of 3-0.4 Å (4-30 keV), the specimen thickness can be from 100μm-2 cm and 10 μm-3 mm, respectively.Synchrotron X-radiation has the potential for better resolution because of the higher intensity, which allows the use of a narrower beam. There is also the possibility of determining individual element 3-D distributions from measurements on either side of the absorption edges because of the continuous nature of the spectrum and also the possibility of doing this from X-ray fluorescence measurements. To investigate these possibilities, a tomographic apparatus has been built based on the availability of accurately ground, tungsten carbide balls. Metrological assessment shows that the specimen remains within <1 μm of the required position during translation and rotation. Preliminary X-ray tomographic studies with a 4-μm diameter beam have been started at the Daresbury laboratory synchrotron source.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Transmission Electron Microscopy
Overview of Microscopy Techniques
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...