Intrapulmonary percussive ventilation superimposed on conventional mechanical ventilation: comparison of volume
Guillaume Riffard1, Julien Buzenet2, Claude Guérin3
1Service de Réanimation Polyvalente, Hôpital Nord, Centre Hospitalier Universitaire de Saint-Etienne, Saint-Etienne, France.
Background:
Previous bench studies suggest that dynamic hyperinflation may occur if intrapulmonary percussive ventilation (IPV) is superimposed on mechanical ventilation in volume controlled continuous mandatory ventilation (VC-CMV) mode. We tested the hypothesis that pressure controlled continuous mandatory ventilation (PC-CMV) can protect against this risk.
Methods:
An ICU ventilator was connected to an IPV device cone adapter that was attached to a lung model (compliance 30 mL/cm H2O, resistance 20 cm H2O/L/s). We measured inspired tidal volume (VTI) and lung pressure (Plung). Measurements were first taken with IPV off and the ICU ventilator set to VC-CMV or PC-CMV mode with a targeted VTI of 500 mL. For each mode, an inspiratory time (TI) of 0.8 or 1.5 s and PEEP 7 or 15 cm H2O were selected. The experiments were repeated with the IPV set to either 20 or 30 psi. The dependent variables were differences in VTI (ΔVTI) and Plung with IPV off or on. The effect of VC-CMV or PC-CMV mode was tested with the ICU ventilators for TI, PEEP, and IPV working pressure using repeated measures of analysis of variance.
Results:
At TI 0.8 s and 20 psi, ΔVTI was significantly higher in VC-CMV than in PC-CMV. PEEP had no effect on ΔVTI. At TI 1.5 s and 20 psi and at both TI values at each psi, mode and PEEP had a significant effect on ΔVTI. With the ICU ventilators at TI 1.5 s, PEEP 7 cm H2O, and 30 psi, ΔVTI (mean ± SD) ranged from -27 ± 25 to -176 ± 6 mL in PC-CMV and from 258 ± 369 to 369 ± 16 mL in VC-CMV. The corresponding ranges were -15 ± 17 to -62 ± 68 mL in PC-CMV and 26 ± 21 to 102 ± 95 mL in VC-CMV at TI 0.8 s, PEEP 7 cm H2O, and 20 psi. Similar findings pertained to Plung.
Conclusions:
When IPV is added to mechanical ventilation, the risk of hyperinflation is greater with VC-CMV than with PC-CMV. We recommend using PC-CMV to deliver IPV and adjusting the trigger variable to avoid autotriggering.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...