Reduced z-axis coverage in multidetector-row CT pulmonary angiography decreases radiation dose and diagnostic
N Michalakis1, C Keyzer, V De Maertelaer
1Department of Radiology, Hôpital Erasme, Université libre de Bruxelles, Brussels, Belgium.
Objective:
To investigate the effect of a two-third reduction of the scanned length (i.e. 10 cm) on diagnosis of both pulmonary embolism (PE) and alternative diseases.
Methods:
247 consecutive patients suspected of acute PE had a CT pulmonary angiography (CTPA) of the thorax (standard length, L). Based on this acquisition, a second set of images was created to obtain a scan length of 10 cm caudally to the aortic arch (l). Images were anonymized, randomized and interpreted by two independent readers. The quality of enhancement, the presence of PE and the possible alternative and/or complementary diagnoses were recorded. A McNemar exact test investigated differences in discrepancies between readers and between scan lengths.
Results:
57 (23%) patients had an acute PE. Among l sets, PE was missed by both readers in one (1.8%) patient, because the unique clot was localized in a subsegmental artery out of the 10-cm range. There were discrepancies between L and l sets in 9 (3.6%) and 11 (4.5%) patients, by Readers 1 and 2 (p=0.820), respectively. Discrepancies between the readers of L sets and those between both sets were not different regardless of the reader (p>0.99). There were discrepancies between both sets for alternative and/or complementary diagnoses in 43 (17.2%) patients.
Conclusion:
Although its performance in diagnosing PE is maintained, CTPA should not be restricted to a range of 10 cm centred over the pulmonary hilum, because alternative and/or complementary diagnoses could be missed.
Advances In Knowledge:
(1) A 10-cm CTPA acquisition reduces the radiation dose by two-thirds as compared with a standard one, but does not impair the accuracy for the diagnosis of PE. (2) Significant alternative diagnoses are missed in 17.2% of patients when reducing the acquisition height to 10 cm.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT