Related Experiment Video
Updated: May 5, 2026

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
Cement augmentation of hip implants in osteoporotic bone: how much cement is needed and where should it go?
A Sermon1, L Hofmann-Fliri, R G Richards
1AO Research Institute Davos, Davos, Switzerland; Department of Traumatology, University Hospitals Gasthuisberg, Leuven, Belgium; Department of Development and Regeneration, KU Leuven, Belgium.
Abstract:
Several studies proved the beneficial effect of cement augmentation of proximal femoral nail antirotation (PFNA) blades on implant purchase in osteoporotic bone. We investigated the effect of different localizations and amounts of bone cement. Polyurethane foam specimens were instrumented with a PFNA blade and subsequently augmented with PMMA bone cement. Eight study groups were formed based on localization and amount of cement volume related to the blade. All specimens underwent cyclic loading with physiological orientation of the force vector until construct failure. Foam groups were compared between each other and to a cadaveric control group. The experiments revealed a significant dependency of implant purchase on localization and amount of cement. Biomechanically favorable cement positions were found at the implant tip and at the cranial side. However, none of the tested augmentation patterns performed significantly inferior to the cadaveric benchmark. These findings will allow surgeons to further reduce the amount of injected PMMA, decreasing the risk of cement leakage or cartilage damage.
More Related Videos
09:31Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Related Concept Videos
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Hydration of Cement
Aggregate Cement Ratio
Types of Cement II
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...