Related Experiment Video
Updated: May 5, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
What is a Suitable Pressure for the Abdominal Drawing-in Maneuver in the Supine Position Using a Pressure Biofeedback
1Department of Physical Therapy, Graduate School of Catholic University of Pusan.
Abstract:
[Purpose] The aim of this study was to determine the appropriate pressure variation for performing a successful abdominal drawing-in maneuver (ADIM). The abdominal muscle thickness variations and contraction ratios were examined in relation to pressure variations using a Pressure Biofeedback Unit (PBU) during an ADIM in the supine position. [Methods] The PBU was placed identically between the lumbar lordosis of 20 healthy subjects (12 males and 8 females) and the pressure of the PBU was maintained at 40 mmHg. Then, while the subjects performed ADIM at four random pressure variations (0, 2, 4, or 6 mmHg), the thicknesses of the transversus abdominis (TrA), the internal oblique abdominal muscle (IO), and the external oblique abdominal muscle (EO) were measured using ultrasonography. [Results] Pressure increases of 0-2 mmHg resulted in significant decreases in IO and EO thicknesses compared to pressure increases of 6 mmHg. Increases of 0-2 mmHg also resulted in significant decreases in IO+EO and EO contraction ratios compared to pressure increases of 6 mmHg, while the preferential activation ratio of the TrA was significantly increased. [Conclusion] Compared to the other pressure increases, an increase of 0-2 mmHg effectively regulated the thicknesses and contraction ratios of superficial muscles such as IO and EO, rather than the thickness and contraction ratio of the TrA, showing high and indirect preferential activation ratios for TrA. Therefore, for successful ADIM, rather than using large PBU pressure increases, exercises that promote slight increases of around 0-2 mmHg from a baseline of 40 mmHg are desirable.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure

