Related Experiment Video
Updated: May 5, 2026

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Clinical correlation of brachial artery flow-mediated dilation in patients with systemic sclerosis
Takehiro Takahashi1, Yoshihide Asano, Eisuke Amiya
1Department of Dermatology, University of Tokyo Graduate School of Medicine , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan.
Objective:
To investigate the clinical significance of flow-mediated dilation (FMD) in systemic sclerosis (SSc).
Methods:
Thirty-three SSc patients and 12 healthy controls were studied. Ultrasound assessment of the brachial artery FMD was performed on all subjects. The results were expressed as the percentage of increase in brachial artery diameter following hyperemia.
Results:
Limited cutaneous SSc (lcSSc) patients had significantly lower FMD values than healthy controls (5.3 ± 2.7 versus 7.7 ± 2.0 %, p < 0.05), while the values in diffuse cutaneous SSc (dcSSc) patients (6.7 ± 4.0 %) were comparable to those in lcSSc patients and healthy controls. Although FMD values did not correlate with any clinical features in dcSSc patients, there was an inverse correlation between FMD values and disease duration in lcSSc patients (r = -0.64, p < 0.05). Furthermore, lcSSc patients with decreased FMD values showed significantly higher prevalence of digital ulcers and elevated right ventricular systolic pressure than those with normal values (for each; 75 versus 10 %, p < 0.05).
Conclusion:
The FMD values represent the severity of vascular damages, which progress along with disease duration and lead to digital ulcers and pulmonary arterial hypertension, in lcSSc patients.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies

