Related Experiment Video
Updated: May 5, 2026

Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Synthesis, radiosynthesis and first in vitro evaluation of novel PET-tracers for the dopamine transporter:
Christina Rami-Mark1, Birgit Bornatowicz, Cornel Fink
1Division of Nuclear Medicine, Radiochemistry and Biomarker Development Unit, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria; Department of Inorganic Chemistry, University of Vienna, Waehringer Strasse 42, A-1090 Vienna, Austria.
Introduction:
Present data indicate that merging beneficial structural elements from previously published DAT-ligands highest DAT affinity, selectivity and a suitable metabolic profile should be achieved. This combination led to the development of IPCIT and FE@IPCIT.
Methods:
Precursor synthesis was done starting from cocaine in a six step reaction. O-[(11)C]-methylation was established using [(11)C]methyl iodide, optimized and subsequently automated. Small scale (18)F-fluroroethylation as well as optimization of reaction parameters and automation were performed. Affinity and selectivity of the candidate substances were tested in standard binding experiments on human membranes. Metabolic stability and blood-brain-barrier (BBB) penetration were determined.
Results:
Precursor compound, IPCITacid, and reference compounds, IPCIT and FE@IPCIT, were obtained in 4.9%, 12.7% and 4.1% yield, respectively. Automated radiosynthesis of [(11)C]IPCIT yielded 1.9 ± 0.7 GBq (12.5 ± 4%, corrected for decay). Optimum parameters for (18)F-fluoroethylation were 110 °C for 15 min under TBAH catalysis, yielding 67 ± 16 % radiochemical incorporation. Affinity was determined as 1.7 ± 0.6 nM for IPCIT, 1.3 ± 0.2 nM for FE@IPCIT and 37 ± 13 nM for the precursor molecule, IPCIT-acid. Results from in vitro and in silico evaluations revealed high stability but also high lipophilicity.
Conclusion:
Present data indicate high affinity and stability of both IPCIT and FE@IPCIT. Radiolabelling, optimization of reaction parameters and automation succeeded. On the other hand, data concerning BBB-penetration are not promising.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)
