Related Experiment Video
Updated: May 5, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
The design of cost-effective air quality monitoring networks
1Dept. of Industrial Engineering, University of Toronto, M5S 1A4, Toronto, Ontario, Canada.
Abstract:
A statistical measure of information content is used as a means for assessing the effectiveness of a particular monitoring network configuration. This measure is directly related to the precision with which the network can estimate the level of air quality in the region. Each potential site in the network can contribute to an increase in the overall precision of the estimate. The amount of increase is determined by the degree of dependence, displayed by observed pollutant concentrations, between potential sites.A statistical procedure is used to combine the observed pollution dynamics and the measurement network in order to assess network effectiveness. An iterative application of this procedure leads to the design of the most effective network subject to a specified budget constraint.