Elimination of ammonia interference in acidimetric determination of sulphur dioxide
A Si Ović1, M Fugaš, M Gentilizza
1Institute for Medical Research and Occupational Health, Zagreb, Yugoslavia.
Abstract:
Ammonia interference in acidimetric determination of sulphur dioxide can be eliminated by separate determination of ammonia in the same sample and by correction of results. However, with this addition the procedure is no longer simple.To avoid two separate determinations a selective absorption of ammonia from the air stream before it enters the absorbent solution for SO2 has been considered. Several absorbents used to remove or to collect ammonia for subsequent determination were tested in the laboratory. Whatman No. 1 (or 41) filter papers impregnated with 3% oxalic acid solution in ethanol proved to be the most efficient for ammonia retention without an effect on SO2. In a comparative testing over 52 days at a permanent sampling station no statistically significant difference was observed between two trains with impregnated filters and a third train where correction for ammonia, separately determined in the same sample, was performed.Regression analysis, however, showed that the results obtained in the third train are more dispersed due to accumulated errors in two analyses at low concentration levels further aggravated by conversion of ammonia to equivalent SO2 concentrations. The removal of ammonia with impregnated filters gives better precision with less inconvenience and is therefore preferable.
More Related Videos
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
Amines to Sulfonamides: The Hinsberg Test
Generally, a primary amine reacts with the Hinsberg reagent to produce an N-substituted benzenesulfonamide. The electron-withdrawing sulfonyl...
Precipitation and Co-precipitation