Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Automated detection of perinatal hypoxia using time-frequency-based heart rate variability features
Shiying Dong1, Boualem Boashash, Ghasem Azemi
1UQ Centre for Clinical Research, The University of Queensland, Herston, QLD, Australia, shiying.dong@uqconnect.edu.au.
Perinatal hypoxia is a cause of cerebral injury in foetuses and neonates. Detection of foetal hypoxia during labour based on the pattern recognition of heart rate signals suffers from high observer variability and low specificity. We describe a new automated hypoxia detection method using time-frequency analysis of heart rate variability (HRV) signals. This approach uses features extracted from the instantaneous frequency and instantaneous amplitude of HRV signal components as well as features based on matrix decomposition of the signals' time-frequency distributions using singular value decomposition and non-negative matrix factorization. The classification between hypoxia and non-hypoxia data is performed using a support vector machine classifier. The proposed method is tested on a dataset obtained from a newborn piglet model with a controlled hypoxic insult. The chosen HRV features show strong performance compared to conventional spectral features and other existing methods of hypoxia detection with a sensitivity 93.3 %, specificity 98.3 % and accuracy 95.8 %. The high predictive value of this approach to detecting hypoxia is a substantial step towards developing a more accurate and reliable hypoxia detection method for use in human foetal monitoring.
Perinatal hypoxia is a cause of cerebral injury in foetuses and neonates. Detection of foetal hypoxia during labour based on the pattern recognition of heart rate signals suffers from high observer variability and low specificity. We describe a new automated hypoxia detection method using time-frequency analysis of heart rate variability (HRV) signals. This approach uses features extracted from the instantaneous frequency and instantaneous amplitude of HRV signal components as well as features based on matrix decomposition of the signals' time-frequency distributions using singular value decomposition and non-negative matrix factorization. The classification between hypoxia and non-hypoxia data is performed using a support vector machine classifier. The proposed method is tested on a dataset obtained from a newborn piglet model with a controlled hypoxic insult. The chosen HRV features show strong performance compared to conventional spectral features and other existing methods of hypoxia detection with a sensitivity 93.3 %, specificity 98.3 % and accuracy 95.8 %. The high predictive value of this approach to detecting hypoxia is a substantial step towards developing a more accurate and reliable hypoxia detection method for use in human foetal monitoring.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: