Sequential extraction of platinum, cisplatin and carboplatin from environmental samples and
Noorbasha N Meeravali1, K Madhavi, R Manjusha
1National Center for Compositional Characterization of Materials, Bhabha Atomic Research Centre, ECIL Post, Hyderabad 500 062, India.
Abstract:
A sequential extraction procedure is developed for the separation of trace levels of hexachloroplatinate, cisplatin and carboplatin from soil, which are then, pre-concentrated using a vesicular coacervative cloud point extraction method prior to their determination as platinum by continuum source ETAAS. Sequential extraction of carboplatin, cisplatin and hexachloroplatinate from a specific red soil is achieved by using the 20% HCl, aqua regia at room temperature and by combination of aqua regia and HF with microwave digestion, respectively. The pre-concentration of these species from the extracted solutions is based on the formation of extractable hydrophobic complexes of PtCl₆(2-) anionic species with free cationic head groups solubilizing sites of the Triton X-114 co-surfactant stabilized TOMAC (tri-octyl methyl ammonium chloride) vesicles through electrostatic attraction. This process separates the platinum from bulk aqueous solution into a small vesicular rich phase. The parameters affecting the extraction procedures are optimized. Under the optimized conditions, the achieved pre-concentration factor is 20 and detection limit is 0.5 ng g(-1) for soil and 0.02 ng mL(-1) for water samples. The spiked recoveries of hexachloroplatinate, cisplatin and carboplatin in water and soil extracts in the vesicular coacervative extraction are in the range of 96-102% at 0.5-1 ng mL(-1) with relative standard deviation of 1-3%. The accuracy of the method for platinum determination is evaluated by analyzing CCRMP PTC-1a copper-nickel sulfide concentrate and BCR 723 road dust certified reference materials and the obtained results agreed with the certified values with 95% confidence level of student t-test. The results were also compared to mixed-micelle (MM)-CPE method reported in the literature.
Related Concept Videos
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...